> ## Documentation Index
> Fetch the complete documentation index at: https://docs.speckle.systems/llms.txt
> Use this file to discover all available pages before exploring further.

> ## Agent Instructions
> These docs describe Speckle as it works today, including everything released in 2026.9. Treat page content as current unless the page or section says it applies only to versions published before 2026.9.
> Content scoped to versions published before 2026.9 (the object graph and root object, Proxies, Receive2, operations.receive, object.children) applies only to model versions in that earlier data format. For versions published in 2026.9, answer from the Object model pages and the SDK migration guides.
> The What's new pages summarise what changed in 2026.9 and link to the page that documents each change. Answer from the linked page rather than from the summary. Legacy (v2) connectors are retired; send questions about them to the community help forum.
> Match guidance to the customer's deployment, model data format, connector, plan and permissions. Self-hosted servers on a release before 2026.9 and compatibility-mode workflows follow the Compatibility mode page. If an unknown version or data format changes the answer, ask one focused question; do not infer the deployment version from the date alone.

# Autodesk Forma Data Management

> Connect and sync models from Autodesk Forma Data Management — the Autodesk cloud platform still widely known as ACC — with Speckle for analytics, dashboards, and automation workflows.

> [!NOTE]
>
> **Autodesk Forma Data Management** is the current name for **Autodesk Construction Cloud (ACC)**;
> labels and URLs may still say ACC. Before anyone can sign in, the integration must be enabled on
> your **ACC Hub**. If no hubs appear after you sign in, ask your IT administrator to follow [Enable
> Autodesk Forma Data Management integration](https://docs.speckle.systems/it-admin/integrations/acc.md).

> [!NOTE]
>
> The Autodesk Forma Data Management integration is available on the **Enterprise** plan. To use it
> on another plan, [talk to
> sales](mailto:sales@speckle.systems?subject=Forma%20Data%20Management%20Integration%20request).

> [!NOTE]
>
> On self-hosted deployments, the integration requires Speckle Enterprise Server and a [license
> key](https://docs.speckle.systems/developers/server/deployment/enterprise-license.md#license-key). See [ACC
> integration](https://docs.speckle.systems/developers/server/deployment/enterprise-license.md#optional-acc-integration).

> [!TIP]
>
> Help shape Navisworks workflows: join the NWC/NWD user testing study
> ([details](https://docs.speckle.systems/get-involved/user-testing.md#open-opportunities)).

## Setup

These steps assume the Speckle integration has already been enabled on your organisation's ACC Hub for Forma Data Management. If it hasn't, your IT administrator must complete [Enable Autodesk Forma Data Management integration](https://docs.speckle.systems/it-admin/integrations/acc.md) first.

**1. Open ACC in your project**

Open the project in Speckle, then select **Integrations** → **ACC** in the project sidebar. You
should see **Connect to ACC** the first time.

**2. Sign in to Autodesk**

Select **Connect to ACC**, sign in to your Autodesk account, and select **Allow** in the
authorization dialog. You should see your hubs and projects in the selectors at the top.

**3. Pick files to sync**

Choose a hub and project, browse the folders, and select the files you want to sync. For Revit
files, optionally set the reference point and what to publish. See [Revit
options](#revit-options).

**4. Create the sync**

Select **Create sync**. Each file gets its own Speckle model, and changes in Autodesk cloud
storage sync automatically. You should see the new syncs in the **Syncs** panel.

## Supported file formats

Cloud sync accepts the same file formats as file uploads. See [Supported file
formats](https://docs.speckle.systems/connectors/direct-uploads/introduction.md#supported-file-formats).

> [!NOTE]
>
> ACC sync writes the 2026.9 data format. If a script or report downstream of Speckle still needs
> the earlier format, your workspace can use compatibility mode until **1 November 2026**, and it
> accepts fewer formats. See [Compatibility mode](https://docs.speckle.systems/it-admin/compatibility-mode.md) and [Speckle's new
> data model](https://docs.speckle.systems/workspaces/data-model-migration.md).

> [!NOTE]
>
> Navisworks files (`.nwc` and `.nwd`) are supported for manual upload and Forma Data Management
> sync. Many Autodesk (and other) products can export Navisworks Cache files without requiring a
> Navisworks license, so you can upload those exports to Speckle.

> [!NOTE]
>
> ACC sync has no fixed file-size limit, unlike the **5 GB** direct upload limit. Very large files
> can stress the conversion process: Speckle monitors the conversion queue and scales resources to
> demand, but a single conversion that exceeds the capacity of one conversion process can fail. If
> that happens, we follow up with you. If you plan to sync files around **5 GB** regularly, [talk to
> us](mailto:support@speckle.systems) first.

> [!NOTE]
>
> Reference point options apply only to Revit (`.rvt`) files, in uploads and in Forma Data
> Management (ACC) syncs. Other formats, including IFC and Navisworks, are placed using the
> coordinates saved in the file. To load a model into Revit at a chosen reference point, use the
> [Revit connector](https://docs.speckle.systems/connectors/revit/revit.md#model-placement).

## Import earlier versions

A sync starts at the file version current when you create it. When the file already had a history in Forma Data Management, or a version failed to sync and a newer one has been published since, you can bring those earlier versions into the same Speckle model yourself.

> [!NOTE]
>
> The import is not offered when:
>
> * the version is older than the version history your plan keeps
> * you lack the permission to edit the sync
> * the sync is paused
> * the workspace runs in [compatibility mode](https://docs.speckle.systems/it-admin/compatibility-mode.md)

**1. Open the sync's settings**

Open the model and expand the settings on its sync card.

**2. Select Import earlier versions**

A dialog lists the file's versions as Forma Data Management records them, newest first. Versions
already synced or currently syncing are marked and cannot be selected.

**3. Select up to five versions, then Import**

Each version runs as its own sync attempt, oldest first. You should see the runs appear in the
sync activity below the card.

An imported version is dated when it was created in Forma Data Management, so it takes its place in the model's history and the newest file version stays the latest version in Speckle. For a longer history, repeat the import in rounds of five.

## Revit options

Expand a selected Revit (`.rvt`) file to set its options before you create the sync. These options
apply only to Revit files.

### Reference point

Choose which Revit coordinate origin the model is aligned to: **Internal Origin** (default),
**Project Base Point**, **Survey Point**, or **Shared Coordinates**. If you are aligning multiple
models, use the same reference point across related Revit syncs to avoid placement mismatches.

> [!WARNING]
>
> If your workspace uses compatibility mode, do not select **Shared Coordinates**. The older
> conversion path cannot process it and the sync fails. Use **Internal Origin**, **Project Base
> Point**, or **Survey Point** instead.

### What to publish

**Publish method** is **Entire model** by default: all supported elements from the entire model
are synced. This is the recommended option for a complete representation of your model and the
most data for analytics and dashboards.

To sync only part of the model, change the publish method:

* **By View**: enter a view name to sync only the elements visible in that view. The name must match
  a view in your Revit model exactly (case-sensitive). Once you enter a view, you can also choose to
  append rooms, areas, or both.
* **By Category**: pick the Revit categories to sync.

> [!WARNING]
>
> If the specified view name doesn't exist in the model, the sync will fail. Make sure the view name
> matches exactly.

## Linked Revit models

Sync only the host Revit file: its linked Revit models come with it. Each time the sync runs,
Speckle fetches the models the host links from Forma Data Management and converts them together
with the host into **one version of one Speckle model**, the host's. You don't select the linked
files or create syncs for them.

* **Which version of a link**: the version the host file was published or uploaded against.
* **Which links**: Revit (`.rvt`) links only, up to 100 per version. Other linked or imported
  files, such as DWG, IFC, point clouds, or PDFs, are left out.
* **When links update**: a new version of a linked model does not run the host's sync. The next
  host version picks it up, or select **Trigger now** on the host's sync to bring it in sooner.

A link that cannot be fetched does not fail the sync: the host converts with the links that
remain. To see which links a version includes, open the version in the viewer and check
**Linked files** on the [Health](https://docs.speckle.systems/3d-viewer/exploration.md#model-health) panel.

> [accordion] Is the connection read-only?
>
> Yes. Speckle establishes a read-only connection with Autodesk Forma Data Management (ACC), which means we can sync and analyze your data but can't modify the original files. This ensures data integrity and security.

> [accordion] How often do files sync?
>
> Once you've created a sync model, each new version published to Autodesk Forma Data Management triggers one sync attempt. You don't need to manually trigger ongoing synchronization. A version whose attempt fails can be retried from the sync's status until a newer version is published; after that, bring it in with [Import earlier versions](#import-earlier-versions). See [Sync guarantees](https://docs.speckle.systems/it-admin/integrations/introduction.md#sync-guarantees).

> [accordion] Why are my models in the wrong location?
>
> For **Revit** ACC syncs, use the reference point in the file's options to control placement for coordination workflows. If the selected reference point does not match your downstream model setup, placement can still appear offset. Reference point options are **not** available for IFC or Navisworks ACC syncs—adjust placement in those workflows using your authoring tool or the relevant connector where applicable.
> For project-by-project control and advanced receive options, you can also use the [Revit connector](https://docs.speckle.systems/connectors/revit/revit.md).

> [accordion] Can I get a linked model as its own Speckle model?
>
> Yes. Create a separate sync for the linked file. It gets its own Speckle model and version
> history, and it still appears inside the host's versions. See [Linked Revit
> models](#linked-revit-models).

> [accordion] Why is a linked model missing from my version?
>
> Only Revit links are included, and a link that cannot be fetched is left out without failing
> the sync. Check that the linked file is still in Forma Data Management and that the Autodesk
> account connected to the sync can open it, then select **Trigger now** on the host's sync.

> [accordion] What if my sync fails?
>
> Common causes include file access issues, authorization problems, or unsupported file formats. Check that:
>
> * The file is accessible
> * Your permissions are correct
> * The file is in a [supported format](#supported-file-formats) for your workspace's upload mode
>
> A failed attempt is not retried automatically. If it is the sync's most recent attempt, retry it
> from the sync's status once the cause is fixed; if a newer version has been published since,
> use [Import earlier versions](#import-earlier-versions) to sync it. See [Sync
> guarantees](https://docs.speckle.systems/it-admin/integrations/introduction.md#sync-guarantees). Contact support if issues
> persist.

> [accordion] Can I use the integration on another plan?
>
> The integration is available on the **Enterprise** plan. To use it on another plan, talk to sales at
> [sales@speckle.systems](mailto:sales@speckle.systems).

> [accordion] What's the difference between the Forma Data Management integration and other integrations?
>
> The Forma Data Management (ACC) integration connects Speckle to Autodesk cloud construction data and enables automatic synchronization. Unlike other integrations that require manual file uploads or connectors, cloud syncs happen automatically when files are updated.

> [accordion] Can I use Autodesk Forma Data Management models with Speckle Intelligence?
>
> Yes. Once synced, your models can be used with Speckle Intelligence for analytics, dashboard creation, and generating insights from your construction data.

## Roadmap

| Feature | Status |
| - | - |
| Forma Data Management account connection and authorization | ✅ Complete |
| Revit (`.rvt`) file synchronization | ✅ Complete |
| IFC (`.ifc`) file synchronization | ✅ Complete |
| Automatic sync on file updates | ✅ Complete |
| Basic sync status monitoring | ✅ Complete |
| Enhanced UI/UX for sync management | ✅ Complete |
| Import earlier file versions from ACC history | ✅ Complete |
| Linked Revit models synced with the host file | ✅ Complete |
| Advanced sync configuration options | 🔄 In Progress |
| Improved error handling and reporting | 🔄 In Progress |

## Getting help

For questions, contact Speckle support or visit the [Speckle Community](https://speckle.community/).


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.