Skip to main content
Revit Parameter Updater is in beta and available only on workspaces where it has been explicitly enabled. The feature is limited to Revit at this stage.If you do not yet have access and would like to join the beta, fill out the registration form: Request access to Revit Parameter Updater.
Revit Parameter Updater lets you review and batch-edit Revit element parameters from a Speckle dashboard, then apply those changes back to the Revit model. Each batch of edits is logged as an Issue so you can track what changed and why. [[PLACEHOLDER - Revit connector (DUI) on the left publishing a model, Speckle dashboard with the Parameter Updater widget on the right]]

Prerequisites

Before you begin, confirm you have:
  • A workspace where Revit Parameter Updater has been enabled by the Speckle team.
  • The Speckle Revit connector installed and signed in.
  • A Revit model that has been published to a Speckle project at least once.

Where to find Revit Parameter Updater

In any dashboard, open the widget sidebar and scroll to the Data Conditioning category at the bottom. Drag the Parameter Updater widget onto the canvas. If you do not see the Updater category, Revit Parameter Updater has not been enabled for your workspace.

End-to-end workflow

1

Publish a model from Revit

Open your Revit project and use the Speckle Revit connector to publish it to your target project and model. Wait for the publish to complete so you have at least one Revit model version available as a dashboard data source.
If you want to edit or populate empty parameters, make sure to enable Send null/empty parameters in the connector settings before sending your model to Speckle.
2

Create a dashboard with that model

In the Speckle web app, go to your workspace Dashboards, create or open a dashboard, and add a Model Viewer widget that points at the published Revit model and version. You should see the model rendered so the dashboard can read elements and parameters.
3

Configure the Parameter Updater widget

Add the Parameter Updater widget from the Data Conditioning category and configure its settings. Pick one or more Revit model versions as data sources, choose editable and read-only columns (fields under properties are editable), and optionally group rows by a property such as level or type so you see a grouped table of Revit elements. [[PLACEHOLDER - Widget configuration sidebar showing data sources, Columns, and Group by]]
4

Review and edit Revit parameters

In the table, edit parameters directly in cells, set values for an entire group from the group header, or update only selected elements using the selection row; cells may be editable, read-only, or marked as “Missing parameter” when the element does not have that field. When you have unsaved edits, a footer bar appears at the bottom of the widget showing the number of pending changes with Discard and Submit change requests actions. [[PLACEHOLDER - Parameter Updater table with editable, read-only, and missing parameter cells plus footer bar]]
5

Submit a change request as an Issue

Click Submit change requests in the footer bar and fill in the dialog with a title, status, optional tracking fields, and a description that summarises the changes. When you submit, Speckle creates an Issue with a screenshot, viewer state, and the parameter changes stored as objectDeltas so you can track what changed and why.
6

Apply the approved changes in Revit

In Revit, open the same project, find the published model card in the Speckle connector, and open the related Issue via the Issues icon. Use the Apply changes action so the connector sends the batch of parameter updates, validates each one, and applies them in a single transaction, showing a toast that reports whether all, some, or none of the parameters were updated. [[PLACEHOLDER - Revit connector Issue panel with Apply changes action and success toast]]

What you can and cannot edit

Editable

  • Instance, Type, and System Type parameters exposed under properties in the Revit object tree.
  • Text, numeric, boolean (Yes/No), and some ElementId-backed parameters (for example materials and levels that can be resolved by name).

Not editable

  • Read-only parameters – system-controlled values that the Revit API does not allow you to change.
  • Missing parameters – elements that do not have the selected parameter. The widget shows “Missing parameter” and skips these during bulk edits.
  • Linked model elements – elements from linked Revit models are blocked. The connector reports “Cannot modify elements from a linked model”.
  • Parameters not published – parameters that were not included when the model was published will not appear in the widget. [[PLACEHOLDER - Full Parameter Updater widget: table with editable, read-only, and missing parameter cells highlighted, footer bar with pending changes and Submit button]]

Known limitations

LimitationDetail
Revit onlyRevit Parameter Updater currently works with Revit models only.
Linked modelsElements from linked models cannot be updated. Requests targeting linked elements are skipped with an error.
Path formatThe parameter path must resolve to three segments (scope, group, name) after stripping prefixes. If the path structure does not match, the update is rejected.
Renamed or removed paramsIf a parameter no longer exists or has been renamed since the model was published, the connector reports “Parameter not found”.
Read-only enforcementSome parameters appear editable in the dashboard but are marked read-only in Revit. The connector rejects these at apply time.
Unit handlingNumeric values are scaled to Revit internal units. Extreme values or unit mismatches can produce failures.
ElementId parametersSetting ElementId values by raw ID is not yet supported. The connector attempts to resolve by element name (materials, levels, phases). Other types may not resolve.
No automatic Issue pollingThe connector does not automatically poll for Issues. You must open the UI and trigger the apply action.

What to test

For beta testing, focus on:
  • Happy path – update a small set of parameters (for example door marks or wall types) and confirm they update correctly in Revit.
  • Mixed results – include parameters that should fail (read-only, missing, linked elements) alongside valid edits. Confirm the widget flags uneditable cells and Revit reports partial success with grouped errors.
  • Scale – try batches of tens to low hundreds of elements and check that the experience remains usable and messaging is clear.
  • Issue traceability – confirm each submission creates a single Issue with a useful screenshot, viewer state, and description so you can audit what was changed later.
[[PLACEHOLDER - Scenario montage: Several dashboards and Issues for different Revit models]]

Feedback and next steps

  • If something behaves unexpectedly, note:
    • The parameter path and element type.
    • The exact error text from the Revit toast.
    • The Issue link from the Speckle web app.
  • Share those details when reporting bugs so we can reproduce them quickly.
  • If you want a walkthrough:
    • Book a short session for a live demo and onboarding.

Book a Revit Parameter Updater session

Provide feedback on Revit Parameter Updater currently released in Beta.
Last modified on March 31, 2026